Astigmatism Research - Cornea, Retina, Treatment, Types, Signs, Tests

Astigmatism Research Today is a free monthly online journal that collates and summarizes the latest research about Astigmatism, including details on cornea, retina, treatment, types, signs, tests.


Astigmatism Research Today

Home

View Latest Issue

Information About Astigmatism

Books on Astigmatism

Advertising in Research Today

View Other Research Today Publications



The application of a computerised videokeratography (CVK) based contact lens fitting software programme on irregularly shaped corneal surfaces.

Nosch DS, Ong GL, Mavrikakis I, Morris J

Sussex Eye Hospital, Brighton and Sussex University Hospital, Brighton, UK.

PURPOSE: To explore the success of the application of a computerised videokeratography (CVK) software system for the fitting of rigid gas permeable (RGP) contact lenses (CLs) on irregular corneal surfaces and compare it to the standard diagnostic fitting procedure. METHODS: This was a comparative prospective study, over a 1-year period (2004-2005). It included 41 RGP CL wearers (68 eyes) with irregular corneal surfaces. Of these, 51 (75%) had keratoconus, 7 (10%) corneal scarring (infectious or traumatic), 6 (6.82%) corneal transplants, 2 (2.9%) astigmatism, and 2 (2.9%) aphakia. Each eye was being re-fitted with a new RGP CL based on a topographical measurement in conjunction with a CL fitting software programme. The performance of the CLs was evaluated regarding visual outcome, fitting characteristics, and efficiency of the fitting procedure. RESULTS: Of the 68 eyes, 53 (77.94%) chose the CL fitted using the CVK software system, 9 (13.24%) chose the CL fitted using the standard procedure, and 6 (8.82%) showed no preference for either CL. There was a statistically significant improvement regarding visual outcome [contrast sensitivity at the spatial frequencies of 0.66 (p=0.029), 3.40 (p=0.008), and 17 (p=0.032), subjective vision (p=0.009)], fitting characteristics [grading scale (p=0.00), lens comfort (p=0.00) and daily wearing time (p=0.002)], and efficiency [number of trial lenses required (p=0.00)] with the CL fitted using the CVK software system. Correlating factors for the likely preference for the CL fitted using the CVK software system were subjective vision (p=0.004), lens comfort (p=0.009), and convenience of the fitting procedure (p=0.023). CONCLUSION: The application of a CVK software system for the fitting procedure of RGP CLs on irregular corneal surfaces was a safe procedure and shown to be more successful and efficient than the standard diagnostic fitting method.

Published 28 August 2007 in Cont Lens Anterior Eye, 30(4): 239-48.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Astigmatism Research Today. All Rights Reserved.



Astigmatism Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Astigmatism Books

Astigmatism - A Medical Dictionary, Bibliography, and Annotated Research Guide to Internet References

Astigmatism - A Medical Dictionary, Bibliography, and Annotated Research Guide to Internet References