Astigmatism Research - Cornea, Retina, Treatment, Types, Signs, Tests

Astigmatism Research Today is a free monthly online journal that collates and summarizes the latest research about Astigmatism, including details on cornea, retina, treatment, types, signs, tests.


Astigmatism Research Today

Home

View Latest Issue

Information About Astigmatism

Books on Astigmatism

Advertising in Research Today

View Other Research Today Publications



On the prediction of optical aberrations by personalized eye models.

Navarro R, González L, Hernández-Matamoros JL

ICMA, Consejo Superior de Investigaciones Cientificas, Universidad de Zaragoza, Zaragoza, Spain. rafealnb@unizar.es

PURPOSE: The purpose of this study is to develop and analyze a method to obtain optical schematic models of individual eyes. Each model should be able to reproduce the measured monochromatic wave aberration with high fidelity. METHODS: First, we choose a generic eye model as the input guess and then apply a two-stage customization procedure. Stage 1 consists of replacing, in the initial generic model, those anatomic and optical parameters with experimental data measured on the eye under analysis. The set of experimental data was that provided by a standard clinical preoperative examination, namely lens topography, ultrasound biometry, and total wave aberration. Then, the second stage is to find the unknown lens structure that would reproduce the measured wave aberration through optical optimization. Two totally different initial eye models have been compared; one considers a simpler constant refractive index for the lens, whereas the second model has a gradient-index (GRIN) lens. RESULTS: This automatic customization method has been applied to 19 eyes with different degrees of spherical ametropia (from +0.4 D to -8 D). Two models have been obtained for each eye (constant and gradient index lens). The results were highly satisfactory, with 100% convergence, and with average RMS prediction errors approximately lambda/100. This is one order of magnitude lower than typical measurement errors. The models with a constant refractive index lens tended to overestimate surface curvatures, whereas for the GRIN model, lens surfaces were too flat. CONCLUSIONS: The proposed method is highly efficient and robust giving a high-fidelity reproduction of the wavefront in all cases attempted so far. Limitations found in reproducing the geometry of the lens seem to be associated with the use of inaccurate models of its refractive index.

Published 14 June 2006 in Optom Vis Sci, 83(6): 371-81.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Astigmatism Research Today. All Rights Reserved.



Astigmatism Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Astigmatism Books

Refractive Eye Surgery<br>A Consumer's Complete Guide: LASIK, IntraLASIK, Epi-LASIK, CK, Implantable Contact Lenses, and Other Surgical Eye Procedures ... Dependence on Glasses and Contact Lenses

Refractive Eye Surgery
A Consumer's Complete Guide: LASIK, IntraLASIK, Epi-LASIK, CK, Implantable Contact Lenses, and Other Surgical Eye Procedures ... Dependence on Glasses and Contact Lenses