Astigmatism Research - Cornea, Retina, Treatment, Types, Signs, Tests

Astigmatism Research Today is a free monthly online journal that collates and summarizes the latest research about Astigmatism, including details on cornea, retina, treatment, types, signs, tests.


Astigmatism Research Today

Home

View Latest Issue

Information About Astigmatism

Books on Astigmatism

Advertising in Research Today

View Other Research Today Publications



Visual performance of AcrySof ReSTOR apodized diffractive IOL: a prospective comparative trial.

Souza CE, Muccioli C, Soriano ES, Chalita MR, Oliveira F, Freitas LL, Meire LP, Tamaki C, Belfort R

Vision Institute, Federal University of São Paulo, São Paulo, Brazil. ce.bsouza@uol.com.br

PURPOSE: Evaluate the visual performance of the AcrySof ReSTOR intraocular lens (IOL) and compare it with the monofocal SA60AT IOL. DESIGN: Prospective, nonrandomized, clinical trial. METHODS: Forty patients (80 eyes) from the Federal University of São Paulo were enrolled in two groups. Twenty-five patients were assigned to the ReSTOR group and 15 patients to the monofocal group. Inclusion criteria were corneal astigmatism <1.0 diopter, potential acuity meter >0.2 logMAR units, and no associated ocular diseases. Parameters analyzed included distance uncorrected and best-corrected visual acuity, near uncorrected and distance corrected visual acuity, intermediate visual acuity, contrast sensitivity (Pelli-Robson chart), stereopsis (Titmus test), reading speed, wavefront measurement (LADARWave aberrometer), and a quality-of-life questionnaire. main outcome measure: Distance and near uncorrected and best distance corrected visual acuity, contrast sensitivity, and reading speed. RESULTS: Distance uncorrected and best-corrected visual acuity in the ReSTOR group were not statistically different from the monofocal group (P = .66). Near uncorrected and distance corrected visual acuity were statistically better in the ReSTOR group than the monofocal group (0.16 +/- 0.13 vs 0.62 +/- 0.09, P < .001, and 0.14 +/- 0.12 vs 0.62 +/- 0.07, P < .001, respectively). The ReSTOR group demonstrated less spherical aberrations compared with the monofocal group (P < .001). Monocular photopic contrast sensitivity was statistically lower in the ReSTOR group (P < .001). Stereopsis and reading speed were not statistically different between the groups. CONCLUSION: The AcrySof ReSTOR IOL provides a satisfactory full range of vision and achieves a more satisfactory quality of life when compared with the monofocal SA60AT IOL, but with lower contrast sensitivity.

Published 8 May 2006 in Am J Ophthalmol, 141(5): 827-832.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Astigmatism Research Today. All Rights Reserved.



Astigmatism Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Astigmatism Books

Astigmatism - A Medical Dictionary, Bibliography, and Annotated Research Guide to Internet References

Astigmatism - A Medical Dictionary, Bibliography, and Annotated Research Guide to Internet References